• Mashup Score: 2

    Background Parametric mapping sequences in cardiovascular magnetic resonance (CMR) allow for non-invasive myocardial tissue characterization. However quantitative myocardial mapping is still limited by the need for local reference values. Confounders, such as field strength, vendors and sequences, make intersite comparisons challenging. This exploratory study aims to assess whether multi-site studies that control confounding factors provide first insights whether parametric mapping values are within pre-defined tolerance ranges across scanners and sites. Methods A cohort of 20 healthy travelling volunteers was prospectively scanned at three sites with a 3 T scanner from the same vendor using the same scanning protocol and acquisition scheme. A Modified Look-Locker inversion recovery sequence (MOLLI) for T1 and a fast low-angle shot sequence (FLASH) for T2 were used. At one site a scan-rescan was performed to assess the intra-scanner reproducibility. All acquired T1- and T2-mappings wer

    Tweet Tweets with this article
    • Multi-site comparison of parametric T1 and T2 mapping: healthy travelling volunteers in the Berlin research network for cardiovascular magnetic resonance (BER-CMR) https://t.co/iVDkxcS82t

  • Mashup Score: 3

    Background Late gadolinium enhancement (LGE) is a valuable part of cardiac magnetic resonance imaging (CMR). In particular, inversion-recovery imaging of LGE, with nulling of the signal from reference areas of myocardium, can have a distinctive pattern in some patients with cardiac amyloid, including both diffuse (relatively faint) subendocardial LGE and a relatively dark appearance of the blood. However, the underlying reasons for this distinctive appearance have not previously been well investigated. Pharmacokinetic modeling of myocardial contrast enhancement kinetics can potentially provide insight into the mechanisms of the distinctive LGE appearance that can be seen in cardiac amyloid, as well as why it may be unreliable in some patients. Methods An interactive three-compartment pharmacokinetic model of the dynamics of myocardial contrast enhancement in CMR was implemented, and used to simulate LGE dynamics in normal, scar, and cardiac amyloid myocardium; the results were compared

    Tweet Tweets with this article
    • Modeling of factors affecting late gadolinium enhancement kinetics in MRI of cardiac amyloid https://t.co/leAGM16EWm

  • Mashup Score: 1

    Background Cardiomyopathy is the leading cause of death in Duchenne muscular dystrophy (DMD). Cardiac magnetic resonance (CMR) parametric mapping sequences offer insights into disease pathophysiology. We propose a novel approach by leveraging T2 mapping in conjunction with T1 and extracellular volume (ECV) mapping to perform a virtual myocardial biopsy. While previous work has attempted to describe myocardial changes in DMD, our inclusion of T2 mapping enables comprehensive categorization of myocardial tissue characteristics of fibrosis, edema, and fat to better understand the pathological composition of the myocardium with disease progression. Methods DMD patients (n = 49; median: 12 years-old) underwent CMR, including T1, T2, and ECV. Categories were defined as normal, isolated high T1 (normal ECV, high T1, normal T2), fibrosis (high ECV, normal or high T1, normal T2), edema (normal or high ECV, normal or high T1, high T2), fat (normal ECV, low T1, high T2) or fibrofatty (high ECV, l

    Tweet Tweets with this article
    • Comprehensive cardiac magnetic resonance T1, T2, and extracellular volume mapping to define Duchenne cardiomyopathy https://t.co/XftrQPfTyt

  • Mashup Score: 4

    Background Cardiovascular magnetic resonance (CMR) has been established as a valuable tool in clinical and scientific cardiology. This study summarizes the current evidence and role of CMR in the guidelines of the European Society of Cardiology (ESC) and is an update of a former guideline analysis. Methods Since the last guideline analysis performed in 2015, 28 new ESC guideline documents have been published. Twenty-seven ESC practice guidelines are currently in use. They were screened regarding CMR in the text, tables and figures. The main CMR-related sentences and recommendations were extracted. Results Nineteen of the 27 guidelines (70.4%) contain relevant text passages regarding CMR in the text and include 92 specific recommendations regarding the use of CMR. Seven guidelines (25.9%) mention CMR in the text, and 1 (3.7%, dyslipidemia) does not mention CMR. The 19 guidelines with recommendations regarding the use of CMR contain 40 class-I recommendations (43.5%), 28 class-IIa recomm

    Tweet Tweets with this article
    • Cardiovascular magnetic resonance in the guidelines of the European Society of Cardiology: a comprehensive summary and update https://t.co/JHmZ1PyZxp

  • Mashup Score: 4

    Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 ‘4D Flow CMR Consensus Statement’. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated conse

    Tweet Tweets with this article
    • 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update https://t.co/PfsohmckaV

  • Mashup Score: 4

    Purpose To investigate the feasibility and clinical utility of a compressed-sensing-accelerated subtractionless whole-body MRA (CS-WBMRA) protocol with only contrast injection for suspected arterial diseases, by comparison to conventional dual-pass subtraction-based whole-body MRA (conventional-WBMRA) and available computed tomography angiography (CTA). Materials and methods This prospective study assessed 86 patients (mean age, 56 years ± 16.4 [standard deviation]; 25 women) with suspected arterial diseases from May 2021 to December 2022, who underwent CS-WBMRA (n = 48, mean age, 55.9 years ± 16.4 [standard deviation]; 25 women) and conventional-WBMRA (n = 38, mean age, 48 years ± 17.4 [standard deviation]; 20 women) on a 3.0 T MRI after random group assignment based on the chronological order of enrolment. Of all enrolled patients administered the CS-WBMRA protocol, 35% (17/48) underwent CTA as required by clinical demands. Two experienced radiologists independently scored the qualit

    Tweet Tweets with this article
    • Subtractionless compressed-sensing-accelerated whole-body MR angiography using two-point Dixon fat suppression with single-pass half-reduced contrast dose: feasibility study and initial experience https://t.co/MypoYFyn7M

  • Mashup Score: 3

    Introduction The use of cardiovascular magnetic resonance (CMR) for diagnosis and management of a broad range of cardiac and vascular conditions has quickly expanded worldwide. It is essential to understand how CMR is utilized in different regions around the world and the potential practice differences between high-volume and low-volume centers. Methods CMR practitioners and developers from around the world were electronically surveyed by the Society for Cardiovascular Magnetic Resonance (SCMR) twice, requesting data from 2017. Both surveys were carefully merged, and the data were curated professionally by a data expert using cross-references in key questions and the specific media access control IP address. According to the United Nations classification, responses were analyzed by region and country and interpreted in the context of practice volumes and demography. Results From 70 countries and regions, 1092 individual responses were included. CMR was performed more often in academic

    Tweet Tweets with this article
    • Worldwide variation in cardiovascular magnetic resonance practice models https://t.co/AhJMBPrhYH

  • Mashup Score: 1

    Background Multiple right ventricular (RV) metrics have prognostic value in pulmonary hypertension (PH). A cardiac magnetic resonance imaging (CMR) derived global ventricular function index (GFI) provided improved prediction of composite adverse outcome (CAO) in adults with atherosclerosis. GFI has not yet been explored in a PH population. We explored the feasibility of GFI as a predictor of CAO in a pediatric PH population. Methods Two center retrospective chart review identified pediatric PH patients undergoing CMR from Jan 2005–June 2021. GFI, defined as the ratio of the stroke volume to the sum of mean ventricular cavity and myocardial volume, was calculated for each patient. CAO was defined as death, lung transplant, Potts shunt, or parenteral prostacyclin initiation after CMR. Cox proportional hazards regression was used to estimate associations and assess model performance between CMR parameters and CAO. Results The cohort comprised 89 patients (54% female, 84% World Health Orga

    Tweet Tweets with this article
    • Ventricular global function index is associated with clinical outcomes in pediatric pulmonary hypertension https://t.co/lufwbhvjKA

  • Mashup Score: 4

    Background The purpose of this meta-analysis was to comprehensively investigate the diagnostic ability of 1.5 T and 3.0 T whole heart coronary angiography (WHCA) to detect significant coronary artery disease (CAD) on X-ray coronary angiography. Methods A literature search of electronic databases, including PubMed, Web of Science Core Collection, Cochrane advanced search, and EMBASE, was performed to retrieve and integrate articles showing significant CAD detectability of 1.5 and 3.0 T WHCA. Results Data from 1899 patients from 34 studies were included in the meta-analysis. 1.5 T WHCA had a summary area under ROC of 0.88 in the patient-based analysis, 0.90 in the vessel-based analysis, and 0.92 in the segment-based analysis. These values for 3.0 T WHCA were 0.94, 0.95, 0.96, respectively. Contrast-enhanced 3.0 T WHCA had significantly higher specificity than non-contrast-enhanced 1.5 T WHCA on a patient-based analysis (0.87, 95% CI 0.80–0.92 vs. 0.74, 95% CI 0.64–0.82, P = 0.02). There

    Tweet Tweets with this article
    • Diagnostic accuracy of whole heart coronary magnetic resonance angiography: a systematic review and meta-analysis https://t.co/E99VuXJTQX